TECHNYL® PROTECT B 50H1 NC L
Halogen & Phosphorus Free FR Copolyamide 66/6 · UL94 V0 @0.4mm · Ultra-Thin Wall FR · Natural Color
UL94 V0 @ 0.4mm
CTI 600V · PLC 0
EN 45545
UL94 @ 0.4mm
CTI (V) · PLC 0
Tensile Modulus (MPa)
Oxygen Index
TECHNYL® PROTECT B 50H1 NC L (previously TECHNYL B 50H1 NATURAL L) is an unreinforced copolyamide 66/6 grade based on a non-phosphorous and non-halogenated flame retardant system, heat stabilized, for injection molding. This flame retardant grade achieves UL94 V0 at 0.4mm ultra-thin wall thickness, offering excellent filling qualities together with good stiffness. This grade is certified to EN 45545 railway standard, suitable for electrical components in railway vehicles.
📋 Product Overview
- Polymer Type: PA66/6 Copolymer (Copolyamide)
- Reinforcement: Unreinforced
- Flame Retardant System: Halogen-free & Phosphorus-free
- UL94 Rating: V0 (0.4/0.75/1.5/3.0mm)
- Electrical Properties: CTI 600V (PLC 0), Dielectric Strength 33 kV/mm
- Heat Stabilized: Yes
- Processing: Injection Molding
- Colors Available: Black, Natural
- Certifications: RoHS, REACH, UL Yellow Card, EN 45545
- Typical Applications: Connectors, Electrical/Electronic Applications
📊 Technical Data Sheet
Physical Properties
Mechanical Properties (DAM / Conditioned)
Electrical Properties
Flammability
✅ UL Yellow Card available (QMF22.E44716)
🌟 Key Advantages
- ✅ Ultra-Thin Wall V0: UL94 V0 rating achieved at 0.4mm thin wall, meeting stringent electrical safety requirements
- ✅ Halogen & Phosphorus Free FR: Environmentally friendly, low corrosion, low smoke
- ✅ Excellent Electrical Properties: CTI 600V (PLC 0), Dielectric Strength 33 kV/mm
- ✅ Excellent Filling Qualities: Excellent flowability for complex connector geometries
- ✅ Good Stiffness: Balanced rigidity and toughness in unreinforced system
- ✅ Heat Stabilized: Long-term thermal aging resistance
- ✅ EN 45545 Railway Certified: Suitable for railway electrical components
- ✅ High Oxygen Index: 33%, excellent flame retardancy
- ✅ RoHS & REACH Compliant: Meets global environmental regulations
⚙️ Processing Conditions
80°C / 2-4 hours
Dew point ≥ -20°C
0.2%
245 – 250°C
250 – 255°C
250 – 260°C
60 – 80°C
(Up to 120°C for high surface quality)
The material is supplied in airtight bags, ready for use. If the virgin material has absorbed moisture, it must be dried with dehumidified air drying equipment (dew point minimum -20°C). Recommended drying time: 2-4 hours.
All flame retardant compounds generate some level of abrasion/corrosion to steel processing equipment. DOMO recommends using steel with high chromium and high carbon content (minimum 16% chromium) for equipment in contact with molten flame retardant compounds. Strictly follow recommended processing conditions to prevent corrosion and ensure product performance.
🎯 Target Applications
Electrical connectors, terminals
Switches, relays, circuit breakers
EN 45545 certified applications
🔗 Related Products
📎 Download & Support
※ Click download links to access the complete technical datasheet. For any questions, please contact us.
Disclaimer: The information provided in this documentation corresponds to our technical knowledge at the date of its publication and does not constitute a specification. DOMO cannot anticipate all conditions under which this information and our products may be used. Users are advised to make their own tests to determine the safety and suitability for their own purposes. Unless otherwise agreed in writing, DOMO sells the product without warranties. Unless specifically indicated, this grade is not suitable for pharmaceutical/medical applications.
Source: DOMO Chemicals Official Technical Data Sheet (TECHNYL PROTECT B 50H1 NC L, previously TECHNYL B 50H1 NATURAL L, Document PID-001657)
Last Updated: June 2026