TECHNYL® PROTECT A 60G1 V30 NC
📌 Product Identification & Compliance
| Polymer Type | PA66 (Polyamide 66) |
| ISO 1043 Abbreviation | PA66-GF30 FR(40) |
| ISO 16396 Designation | PA66,GF30FR(40),MH,S14-100 |
| Processing Technology | Injection Molding |
| Certifications | RoHS, EC 1907/2006 (REACH), UL Listed Product |
| Colors Available | Natural (NC), Grey |
| Form | Pellets |
| Typical Applications | Electrical/Electronic Applications |
✅ Halogen & Red Phosphorus Free Flame Retardant
✅ UL94 V0 (0.75mm) / 5VA Rating
✅ GWFI 960°C — Highest Glow-Wire Flammability Index
✅ 6000+ Hours at 160°C Long-Term Heat Aging
✅ UL F1 Weathering Resistance Rating — Suitable for Outdoor Applications
✅ Excellent Electrical Properties — CTI 600V (PLC 0)
✅ NC Natural Color — Flexible Color Customization
⚡ Physical Properties
🔧 Mechanical Properties (Dry)
| Property | DAM |
|---|---|
| Tensile Modulus (1 mm/min) | 11000 MPa |
| Stress at Break (5 mm/min) | 160 MPa |
| Strain at Break (5 mm/min) | 2.6% |
| Charpy Impact Strength (+23°C) | 60 kJ/m² |
| Charpy Impact Strength (-30°C) | 55 kJ/m² |
| Charpy Notched Impact (+23°C) | 10.5 kJ/m² |
| Charpy Notched Impact (-30°C) | 10 kJ/m² |
| Izod Impact Strength (+23°C) | 50 kJ/m² |
• High Rigidity: Tensile modulus of 11000 MPa and stress at break of 160 MPa provide excellent structural load-bearing capacity.
• Good Impact Resistance: Charpy notched impact reaches 10.5 kJ/m² despite 30% glass fiber reinforcement.
• Excellent Low-Temperature Performance: Mechanical properties well maintained at -30°C, with notched impact of 10 kJ/m².
• No Compromise on Flame Retardancy: Achieves market-leading mechanical properties while maintaining excellent flame retardancy.
• 6000+ Hours at 160°C — This grade can withstand continuous use at 160°C for over 6000 hours with stable mechanical properties.
• Suitable for applications requiring long-term heat resistance, such as engine compartment components and high-temperature electrical equipment.
🌡️ Thermal Properties
| Melting Temperature (10°C/min) | 262°C |
| HDT (1.80 MPa) | 245°C |
⚡ Electrical Properties
| Volume Resistivity | 6.0 × 10¹⁴ Ω·m |
| Surface Resistivity | 2.0 × 10¹⁵ Ω |
| Comparative Tracking Index (CTI) | 600 V (Solution A) |
| CTI Performance Level Category | PLC 0 (Highest Level) |
| Dielectric Strength (1 mm) | 38 kV/mm |
• CTI 600V (PLC 0) — Highest comparative tracking index rating, significantly reducing tracking risk.
• Ultra-High Insulation Resistance: Volume resistivity of 10¹⁴ Ω·m, surface resistivity of 10¹⁵ Ω.
• Excellent Dielectric Strength of 38 kV/mm — Suitable for high-voltage insulation applications.
🔥 Burning Behaviour — UL94 V0 / 5VA / GWFI 960°C
| UL Yellow Card | E170540-563189 |
| Flammability (0.75 mm) | V0 |
| GWFI (0.75 / 1.5 / 3.0 mm) | 960°C / 960°C / 960°C |
| GWIT (0.75 mm) | 775°C |
| GWIT (1.5 mm) | 850°C |
| GWIT (1-3 mm) | 750°C |
| Burning Rate (FMVSS, 1 mm) | < 100 mm/min |
• UL94 V0 (0.75mm) — Achieves highest flame retardant rating at thin-wall thickness.
• 5VA Rating — Meets more stringent flame retardant requirements for high fire-protection grade applications.
• GWFI 960°C — Highest glow-wire flammability index rating, meeting IEC 60335-1 appliance standard requirements.
• Halogen & Red Phosphorus Free — Low smoke and non-corrosive gas emissions during combustion, meeting strictest environmental regulations.
• UL F1 Weathering Resistance Rating — Suitable for outdoor applications, resistant to UV and humidity.
🔧 Processing Conditions
• Drying Temperature/Time: 75-85°C / 2-4 hours
• Dew Point Requirement: < -30°C
• Suggested Max Moisture: 0.2%
• Material is supplied in airtight bags, ready for use. If moisture absorption occurs, use dehumidified drying equipment.
Recommended Melt Temperature:
• 265 – 280°C
Injection Temperatures:
• Rear Zone: 265 – 275°C
• Middle Zone: 265 – 275°C
• Front Zone: 270 – 280°C
Recommended Mold Temperature:
• 60 – 90°C
• Up to 120°C for high surface quality requirements
⚠️ Injection Molding Advice
- Equipment Corrosion Protection — All reinforced flame retardant compounds generate some level of abrasion/corrosion to processing equipment. Use steel with high chromium and high carbon content (minimum 16% chromium).
- Process Window Control — Incorrect processing conditions (temperature, residence time, moisture level) can affect part quality and accelerate equipment wear. Strictly follow this technical data sheet.
- Parameter Adjustability — Processing temperatures are recommendations and can be adjusted based on injection machine size, part geometry, and design.
📋 Product Renaming Information
This grade was formerly known as TECHNYL A 60G1 V30 NATURAL or DOMAMID FR 66G30VOE NC. Domo has integrated it into the TECHNYL PROTECT flame retardant product line. The new designation PROTECT A 60G1 V30 NC more clearly reflects the product’s flame retardant characteristics and technology platform. The material formulation and properties remain unchanged — customers can confidently transition to the new name.